Single Detached House (110) — To add a Dwelling to a Residential Use building (Secondary Suite in the Basement of a Single Detached House). 2 Bedroom 1 Bathroom, Kitchen, Living/Dining, Furnace Room.
Retail and Shops (510) — (03) Interior Alterations — To construct Interior Alterations (kitchen upgrade: new hood, exhaust fan, and MUA unit) for a cafe in an existing commercial building. ”Lerruat Cafe”
Proposal for addition of a new ventilation (make up air system) and energy recovery unit, modification of interior diffusers and electrical life safety. Design includes for option heat pump units to provide auxiliary heat in lieu of existing gas power unit heaters.
Service Stations, Repair Garages (572) — (03) Interior Alterations — To Change Use from Warehouse Sales to Automotive and Equipment Repair Shop, and to construct Exterior Alterations (new rear exit door) and Interior Alterations (install new ventilation equipment) to an existing industrial building. "TNF AUTO"
Interior alterations to an existing semi-detached dwelling, including the remodeling of existing kitchens and washrooms. Work involves strictly non-load-bearing partition removals and layout modifications on the main and second floors. A new washroom is proposed on the third floor, which will be equipped with a mechanical exhaust fan vented to the exterior. The project also includes the vertical enlargement of one existing window on the rear third-floor elevation. The existing finished basement is to remain completely unaltered; no secondary suite, separate entrance, or change of major occupancy is proposed.
Proposed interior alterations for a new commercial kitchen make-up air unit and exhaust fan on theexterior of the building.See also 26-215836 MSA 00 MS
Proposal for first tenant in a new unit within Mount Dennis TTC Station, Interior renovations including minor architectural, HVAC, plumbing and electrical work. Note NB 16-154343.
Proposed interior alterations to existing two-storey row dwelling, including removal of load-bearing walls, construction of a new ground floor powder room, renovation of the existing second floor bathroom, and non-structural partition changes at the basement and second floor. Furnace and duct replacement. No change to the existing building perimeter, height, or footprint.
Interior alterations to the ground floor of an existing single-family dwelling, including the removal and modification of interior partition walls to reconfigure the kitchen and living areas, create a new powder room, and add an entry closet. The project includes associated HVAC distribution upgrades. Exterior work consists of replacing existing rear windows with a new four-panel sliding door and constructing a new uncovered wood deck at the rear, supported by sonotubes. There are no proposed changes to the existing building footprint, gross floor area (GFA), or roofline.
Proposal to remove kitchen facilities and convert the kitchen and dining area to storage space because the ventilation pipers passing through the kitchen reduce the kitchen ceiling height below the required minimum.
Replacement of existing patio windows with new windows and guards at existing eating establishement. No change of use and no change in patron area. New hvac addition for heating and cooling.
Single Detached House (110) — To add a Dwelling to a Residential Use building (Secondary Suite in the Basement of a Single Detached House). 2 Bedrooms, 1 Kitchen, 1 Bathroom, 1 Living area, 1 Laundry room under stairs, 1 Mechanical room, 1 Furnace room
nterior alterations to an existing single-family semi-detached dwelling, including interior layout modifications, removal of select non-load-bearing partitions, widening of an existing load-bearing wall opening with new engineered lintel/support, renovation of existing kitchen and washrooms, removal of basement cooktop to maintain single-family use, installation of a wood-burning fireplace insert within the existing masonry chimney, and associated plumbing and HVAC modifications. No changes to building footprint or exterior openings are proposed.
1) Replace the two existing Make-Up Air Units with new ones. 2) Install new concrete curbs on the ground floor and building roof, complete with a new waterproofing system to accommodate the new equipment. 3) Remove the masonry wall on the ground floor to facilitate the removal of the existing MAU-1 unit and the delivery of the new unit, then rebuild the wall and install a new intake louver.
Interior alterations to an existing office suite, including the demolition and construction of interior partitions and ceilings, construction of new offices and a kitchen, and associated HVAC modifications.
Office Buildings (520) — (03) Interior Alterations — To complete interior alteration (first tenant fit-up for a medical clinic) to the new commercial shell building. (One new RTU)-- Dr. Ahmed, Medical Clinic
MINOR DEMOLITION AND NEW FIT OUT WITH OFFICES, MEETING ROOMS, RECEPTION, IT CLOSET, KITCHENETTE AND STORAGE. HVAC AND PLUMBING ALTERATIONS TO SUIT AND NEW LIGHTING THROUGHOUT.
Interior alterations to an existing office suite, including the demolition and construction of interior partitions and ceilings, construction of new offices and a kitchen, and associated HVAC modifications.
Apartments (310) — (03) Interior Alterations — To construct Interior Alterations for fire restoration of an existing 4 storey residential building. (Restoration includes sound proofing upgrades, fire separation, cosmetic upgrades, electrical distribution system replacement and unit electrical panel replacement, hydronic heating system replacement and HVAC upgrades.) "Final work Phase 2 Blue Ice Project" NOTE: See permit 603913199-002 for Phase 1 exterior and structural work.
BUILDING, PLUMBING, HVAC. DEMOLISH THE EXISTING 1-STOREY BRICK DWELLING. TO CONSTRUCT A NEW 2-STOREY SINGLE DETACHED DWELLING WITH BASEMENT WALKOUT, FRONT PORCH AND REAR DECK.
Proposal for electrical building and RTU equipment relocation including the re-routing of the incoming Toronto Hydro service (3-Phase) to the new building .Refer to 26 182426 BA
Proposal to enclose existing balcony as addition to existing detached SFD. Second-floor addition to an existing detached dwelling: enclosing the existing second-floor balcony to extend the office (approx. 13.5 m²), including new exterior walls, new windows, new headers/lintels, new roof framing over the addition, associated interior renovations, and alterations to the existing HVAC distribution.
Proposed Interior fit-out and architectural alterations for dairy facility expansion, including non-structural walls, Insulated Metal Panels (IMP), doors, and sanitary finishes. Work includes complete installation of mechanical systems (HVAC, plumbing, process exhaust, hydronic piping) , electrical distribution (power, lighting, equipment feeds, fire alarm systems) , and fire suppression systems (sprinklers, standpipes, fire pump integration) as per approved architectural, mechanical, electrical, and fire protection engineering drawings. Excludes structural base building and civil site works.
Installation of Air-Source Heat Pump (ASHP) outdoor unit per townhouse unit at 174 John Garland Blvd. Total of eighteen (18) ASHP units across the property.
Single Detached House (110) — To construct interior alterations to a Residential Use building (Kitchen update and new furnace and air conditioner) and to construct exterior alterations (Changing an existing 60" wide window to sliding patio doors of same width on south wall, and adding a 42" wide window on the east wall.).
Single Detached House (110) — To construct exterior and interior alterations to a Residential Use building (2 new basement windows on left and rear elevations, 2 enlarged basement window on left elevation and Basement development including relocating existing support post, & HVAC system updates, NOT to be used as an additional Dwelling). 2 Bedroom 1 Bathroom, Office, Living room with wet bar, Mech Room.
Drain - Proposal for the addition to Existing TTC Line 2 Pape Station - West Fan Plant. Construction of ventilation shaft and emergency egress building.